Universal Central Control System
HDP-CTL801
The Integrated Controller is designed to be utilized in the sectors of commanding center, automated office system, multi-media room and smart home. With a programmable interactive user interface over configuration protocols, the integrated system provides intelligent networking service, ideal for the establishment of modern commanding and control center. The Controller features 8 two-way serial ports, 8 IR outputs, 8 Relay ports, 8 digital I/O ports and 1 Gigabit Ethernet port, suitable for large-scale application systems to control multiply devices. The Controller is used in a diverse range of installations and applications across industries including emergency alarming centers, C4ISR solutions, governmental administration centers, smart buildings, multi-media conference rooms, multi-functional halls, training centers, showroom, broadcasting studios, and industrial automation.
☆ With 8 two-way serial ports to connect matrixes, projectors or other A/V devices
☆ With 8 IR outputs/one-way serial ports to connect DVD, TV sets, or other home appliances
☆ With 8 relay ports to control lights, doors or curtains
☆ With 8 digital inputs to receive sensor signals
☆ Capable of connecting with Ethernet-control devices for Ethernet monitoring and control
☆ IR learning
☆ Provide a superb-performance Web server, supporting on-line firmware upgrade
☆ Compliant with standard network communication protocols
☆ Password protection against unauthorized accesses
☆ Built-in sync clocks
☆ Standard 1U rack mounting
☆ 220V AC power supply
☆ Support factory reset
Specifications | Technical | |
CPU | ARM Cortex-A53 1.8GHz | |
Operation System | Android 9 | |
RAM | 2GB DDR4 RAM | |
Flash Memory | 8GB EMMC Flash | |
LEDs | 1× IR Learning LED 1× Power LED 1× LAN LED 1× Status LED 8× TX LEDs 8× RX LEDs 8× IR/Serial LEDs 8× Relay LEDs 8× I/O LEDs | |
Connections | ||
COM1/2/3/4 | 4× 9-pin Phoenix Connectors, for two-way RS-232/422/485 serial data communication | |
COM5/6/7/8 | 4× 3-pin Phoenix Connectors, for RS-232 serial data communication | |
IR-SERIAL OUTPUT | 2× 8-pin Phoenix Connectors, for IR transmitting or one way RS-232 serial data communication | |
RELAY OUTPUT | 2× 8-pin Phoenix Connectors, low-voltage relays, isolated, normally open, switching up to 30VDC, 2A / 125VAC, 1A | |
DIGITAL I/O | 2× 5-pin Phoenix Connectors, for digital signal inputting | |
LAN | A standard 10M/100M/1000M Ethernet RJ45 interface | |
USB | 1× USB TYPE A (function reserved) | |
COMPUTER | 1× USB TYPE B | |
H-NET | 1× 4-pin Phoenix Connectors, private bus interface (function reserved) | |
RESET | 1× RESET, for restoring factory default | |
IR | 1× IR learning Window | |
Mechanical | ||
Housing | Metal enclosure with aluminium alloy front panel | |
Color | Black | |
Dimensions | 440mm (W)×200mm (D)×44mm (H) | |
Weight | 2.1kg | |
Installation | Standard 19-inch cabinet (with mounting ears) or flat installation | |
Power Supply | AC110~220V 50/60Hz | |
Power Consumption (Max) | 55W (48W for external power supplies connected via the H-NET port.) | |
Operation Temperature | 32 - 104°F / 0 - 40°C | |
Relative Humidity | 10~90% RH (non-condensing) |